Near infrared (NIR) soil spectral library using the NeoSpectra Handheld NIR Analyzer by Si/Ware

Type: 

Abstract:

Up/to/date information on soil properties and the ability to track changes in soil properties over time are critical for improving multiple decisions on soil security at various scales, ranging from global climate change modeling and policy to national level environmental and development planning, to farm and field level resource management. Diffuse reflectance infrared spectroscopy has become an indispensable laboratory tool for the rapid estimation of numerous soil properties to support various soil mapping, soil monitoring, and soil testing applications. Recent advances in hardware technology have enabled the development of handheld sensors with similar performance specifications as laboratory/grade near/infrared (NIR) spectrometers. Here, we've compiled a hand/held NIR spectral library (1350/2550 nm) using the NeoSpectra Handheld NIR Analyzer developed by Si/Ware. Each scanner is fitted with Fourier/Transform technology based on the semiconductor Micro Electromechanical Systems (MEMS) manufacturing technique, promising accuracy, and consistency between devices. This library includes 2,106 distinct mineral soil samples scanned across 9 of these portable low/cost NIR spectrometers (indicated by serial no). 2,016 of these soil samples were selected to represent the diversity of mineral soils found in the United States, and 90 samples were selected across Ghana, Kenya, and Nigeria. 519 of the US samples were selected and scanned by Woodwell Climate Research Center. These samples were queried from the USDA NRCS NSSC/KSSL Soil Archives as having a complete set of eight measured properties (TC, OC, TN, CEC, pH, clay, sand, and silt). They were stratified based on the major horizon and taxonomic order, omitting the categories with less than 500 samples. Three percent of each stratum (i.e., a combination of major horizon and taxonomic order) was then randomly selected as the final subset retrieved from KSSL's physical soil archive as 2/mm sieved samples. The remaining 1,604 US samples were queried from the USDA NRCS NSSC/KSSL Soil Archives by the University of Nebraska / Lincoln to meet the following criteria: Lower depth <= 30 cm, pH range 4.0 to 9.5, Organic carbon <10%, Greater than lower detection limits, Actual physical samples available in the archive, Samples collected and analyzed from 2001 onwards, Samples having complete analyses for high/priority properties (Sand, Silt, Clay, CEC, Exchangeable Ca, Exchangeable Mg, Exchangeable K, Exchangeable Na, CaCO3, OC, TN), & MIR scanned. All samples were scanned dry 2mm sieved. ~20g of sample was added to a plastic weighing boat where the NeoSpectra scanner would be placed down to make direct contact with the soil surface. The scanner was gently moved across the surface of the sample as 6 replicate scans were taken. These replicates were then averaged so that there is one spectra per sample per scanner in the resulting database. The repository contains: Neospectra_database_column_names.csv: describes the variables (columns) of site and soil data, and the range of NIR and MIR spectra. Both Neospectra_WoodwellKSSL_avg and Neospectra_WoodwellKSSL_reps share the same columns. The CSV is composed of the file name, column name, type, example, and description with measurement unit. Neospectra_project_summary.txt: the summary of the project with purpose, the origin of soil samples, instrumentation, and brief SOP. Neospectra_WoodwellKSSL_avg_MIR.csv: the equivalent MIR spectra of neospectra samples' list that was fetched from the KSSL database and formatted to the OSSL specifications. Neospectra_WoodwellKSSL_avg_soil+site+NIR.csv: soil, site, and Neospectra's NIR. Each row contains the averaged spectra for a given scanner and soil sample (1 spectra per scanner per soil sample). Soil and site info is filled within the same soil sample. Neospectra_WoodwellKSSL_reps_soil+site+NIR.csv: soil, site, and Neospectra's NIR. Each row contains one replicated spectra of a given scanner (6 repeats per scanner per soil sample). Soil and site info is filled within the same soil sample.

Published in: 
Zenodo
Category: 
Agriculture
Date of Publication: 
January 30, 2023
Authors: 
Sanderman ,Jonathan / Smith ,Colleen / Safanelli, José L. /Mitu , Sadia Mannan / Ge , Yufeng / Murad, Omar / Shepherd , Keith
University: 
Woodwell Climate Research Center / University of Nebraska / Lincoln / Innovative Solutions for Decision Agriculture
Read the Article

Ready to Streamline analysis processes for your business ?

See NeoSpectra in action and learn how it can enhance your analysis workflows. Complete the form to request a demo and we’ll be glad to guide you through its unique features.

Contact us
No items found.